APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22261 Issued:2019-08-29
Revised:New
Style 22261 Multiple conductor using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Insulated singlesLabeled or complying with Manufacturer's AWM Procedure having a minimum rating of 80 deg C, 600 Volts.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
InsulationLabeled
JacketExtruded blend of PVC and TPU jacket: 11 mils minimum average thickness, 8 mils minimum thickness at any point. If parallel construction is rippable, the measurements are made after ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.