Rating | 80 deg C,30 Vac, Horizontal Flame, Cable flame. |
|
Conductor | Solid or stranded. |
|
Insulation | Labeled or complying with AWM Procedure having a minimum rating of 80 deg C, 30 Vac |
|
Assembly | Consists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size |
|
Covering | Optional |
|
Jacket | Extruded FRPE. |
| Diameter ofcore assembly under jacket(inch) | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0 - 0.400 | 15 | 12 |
| 0.401 - 0.700 | 30 | 24 |
| 0.701 - 1.000 | 40 | 32 |
| 1.001 - 1.500 | 54 | 43 |
|
Outermost Braid | Required, Polyester material. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|