APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22262 Issued:2019-09-03
Revised:New
Style 22262 Multiple-Conductor Cable using Non-Integral Jacket

Rating80 deg C,30 Vac, Horizontal Flame, Cable flame.
ConductorSolid or stranded.
InsulationLabeled or complying with AWM Procedure having a minimum rating of 80 deg C, 30 Vac
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size
CoveringOptional
JacketExtruded FRPE.
Diameter ofcore assembly under jacket(inch)Minimum average thickness (mils)Minimum thickness at any point (mils)
0 - 0.4001512
0.401 - 0.7003024
0.701 - 1.0004032
1.001 - 1.5005443
Outermost BraidRequired, Polyester material.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.