APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22263 Issued:2019-09-09
Revised:2019-09-22
Style 22263 Multi-conductor cable with Extruded non-integral jacket.

Rating60 deg C, 150 Vdc, Horizontal flame, Cable flame. VW-1 flame
ConductorSolid or stranded.
InsulationExtruded FEP, 4 mils minimum average thickness, 3 mils minimum at any point.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers/or Glass optical fiber optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacket*mils minimum average thicknessmils minimum thickness at any point
0.425 inch or less3024
0.426-0.700 inch4536
0.701-1.000 inch6048
1.001-1.500 inch8064
1.501-2.500 inch11088
2.501 inch and larger140112
* - Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection.

UL and the UL Logo are trademarks of UL LLC © 2024