APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22264 Issued:2019-09-10
Revised:2019-09-09
Style 22264 Multiple Conductor Cable employing Extruded Non-Integral Jacket.

Rating80 deg C, No Voltage Specified, Cable Flame.
InsulationLabeled AWM or Complying with manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers, binders, tapes are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded TPU - 30 mils minimum average thickness, 24 mils minimum at any point.
CoveringExtruded TPU - 12 mils minimum average thickness, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.