APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22269 Issued:2019-10-08
Revised:New
Style 22269 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating90 deg C, 1000 Vac, Cable Flame; Oil Res 60C (optional); Sunlight Res (optional).
InsulationLabeled or Complying with the manufacturer's AWM procedure.
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers, binders, tapes are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
Inner JacketExtruded PVC - 18 mils minimum average thickness, 15 mils minimum thickness at any point.
Outer JacketExtruded FEP
Diameter of assembly under jacket in inchesmils min. avg.mils min. at any point
0-0.350108
0.351-0.5001310
0.501-0.7001512
0.701-1.5002016
1.501-2.5003024
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.