Rating | 105 deg C,1000 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional |
|
Covering | Optional inner layer. |
|
Jacket | TPU, may be extruded in one layer or two non-separable layers. |
| Diameter of core assembly under jacket | Minimum average | Minimum at any point |
| 1.001-1.500 inch | 90 mils | 72 mils |
| 1.501-2.500 inch | 100 mils | 80 mils |
| 2.501 inch and larger | 120 mils | 96 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection of electronic equipment. |
|