APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2228 Issued:1959-05-01
Revised:2008-05-27
Style 2228 SPT-3 Cord.

Rating80 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
ConductorNo. 18 or 16 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationIntegral with Jacket. PVC, 60 mils min average, 54 mils minimum at any point.
AssemblyFour conductors, same as type SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where exposed to temperatures not exceeding 80 deg C; or Internal wiring of electric refrigerators where exposed to temperatures not exceeding 80 deg C or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.
 