Rating | 80 deg C, 30 Vac, Use No. l Horizontal Flame, Use No. 2 Cable Flame. |
|
Conductor | 50 AWG min., solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together or two or more conductors or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional, Extruded PVC, 13 mil minimum at any point or extruded TPE, 6 mil minimum at any point. |
|
Shield | Required for Use No. 2 - Metal Tape and or Metal Braid; |
|
Jacket | Extruded TPU |
| Diameter of Cable under jacket in inches | mils minimum average | mils minimum at any point |
| 0-0.550 | 35 | 28 |
| 0.551-0.800 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Use No. 1 Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. Use No. 2 Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas. |
|