APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22285 Issued:2019-12-29
Revised:New
Style 22285 Multiple conductor cable with extruded non-integral jacket.

Rating90 deg C, 1000 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM File.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional. May be provided under or over covering, if provided.
CoveringOptional.
JacketExtruded TPU.
Diameter of cable under jacketMinimum average thicknessMinimum thickness at any point
1.000 inch or less55 mils44 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024