APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22287 Issued:2020-01-17
Revised:New
Style 22287 Bonded flat ribbon cable.

Rating80 deg C, 600 Vac, Cable flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Two or more jacketed cables are laid parallel and bonded or heat bonded together with a web to form a flat cable. If the cable construction is rippable, measurements of jacket thickness shall be made after ripping.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701 - 1.000 inch45 mils36 mils
1.001 - 1.500 inch60 mils48 mils
1.501 - 2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024