APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22305 Issued:2020-04-07
Revised:2020-04-06
Style 22305 Multiple conductor with extruded insulation.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor32 AWG - 8 AWG, solid or stranded.
InsulationExtruded PE, 3 mils minimum average thickness, 2 mils minimum thickness at any point.
AssemblyTwo insulated conductors laid parallel.
Inner CoveringExtruded PE, thickness not specified.
ShieldRequired
Outer CoveringPolyester Tape (heat sealed). 0.6 mil minimum average thickness, 0.4 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.