APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22308 Issued:2020-06-05
Revised:2020-06-08
Style 22308 Multiple Conductor Cable using Non-Integral Extruded Jacket

Rating105 deg C, -40 deg C, 300 Vac, Horizontal Flame, Cable Flame; Moisture Res 60 (required); Sunlight Res (required).
Conductor50 AWG Min, Solid or Stranded Round.
InsulationExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. Any Recognized Component (QMTT2) PVC Compound acceptable for use on Types THWN and THWN-2.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded TPE, Any Recognized Component (QMTT2) 720 hours sunlight Resistance TPE Compound or See Facing Page for compound.
Diameter of Core Assembly under jacket in inchesminimum average thickness (mils)minimum thickness at any point (mils)
0-0.7003024
0.701-1.0004536
1.001-1.5006548
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.