Rating | 105 deg C, -40 deg C, 300 Vac, Horizontal Flame, Cable Flame; Moisture Res 60 (required); Sunlight Res (required). |
|
Conductor | 50 AWG Min, Solid or Stranded Round. |
|
Insulation | Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. Any Recognized Component (QMTT2) PVC Compound acceptable for use on Types THWN and THWN-2. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded TPE, Any Recognized Component (QMTT2) 720 hours sunlight Resistance TPE Compound or See Facing Page for compound. |
| Diameter of Core Assembly under jacket in inches | minimum average thickness (mils) | minimum thickness at any point (mils) |
| 0-0.700 | 30 | 24 |
| 0.701-1.000 | 45 | 36 |
| 1.001-1.500 | 65 | 48 |
| 1.501-2.500 | 80 | 64 |
| |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|