APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22311 Issued:2020-07-08
Revised:2020-07-14
Style 22311 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating105 deg C,600 Vac Horizontal flame, Optional - 60 deg C Oil, 75 deg C wet.
Conductor40 AWG minimum, solid or stranded.
InsulationLabeled or complying with Manufacturer's AWM Procedure. R/C QMTT2 insulation material rated for 75C water resistance required, when employed for wet location.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of twisted conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional - Extruded TPE, SRPVC, PVC, FEP, PFA, EP or Nylon; 6 mils minimum thickness at any point.
JacketExtruded TPE
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0006048
1.001-1.5008064
1.501-2.50011088
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.