Rating | 80 deg C,30 V, FT2, VW-1, Cable Flame. |
|
Conductor | 36 AWG - 10 AWG, solid or stranded. |
|
Insulation | Extruded TPEE, 7 mils minimum average thickness, 6 mils minimum thickness at any point. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of cable under jacket* | minimum average thickness | mimimum thickness at any point |
| 0.400 inch or less | 24 mils | 19 mils |
| 0.401-0.700 inch | 30 mils | 24 mils |
| 0.701-1.500 inch | 45 mils | 36 mils |
| 1.501-2.500 inch | 60 mils | 48 mils |
| * = Major diameter if flat or oval construction. |
|
Standard | Appliance Wiring Material UL 758. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring, external wiring or interconnection of electronic or electrical equipment. |
|