APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22312 Issued:2020-08-17
Revised:New
Style 22312 Multiple-conductor Cable Using Non-integral Jacket

Rating80 deg C,30 V, FT2, VW-1, Cable Flame.
Conductor36 AWG - 10 AWG, solid or stranded.
InsulationExtruded TPEE, 7 mils minimum average thickness, 6 mils minimum thickness at any point.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded PVC.
Diameter of cable under jacket*minimum average thicknessmimimum thickness at any point
0.400 inch or less24 mils19 mils
0.401-0.700 inch30 mils24 mils
0.701-1.500 inch45 mils36 mils
1.501-2.500 inch60 mils48 mils
* = Major diameter if flat or oval construction.
StandardAppliance Wiring Material UL 758.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring, external wiring or interconnection of electronic or electrical equipment.

UL and the UL Logo are trademarks of UL LLC © 2025