APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22318 Issued:2020-08-03
Revised:2020-08-04
Style 22318 Multiple Conductor Cable using non-integral jacket

Rating105 deg C, 1000 Vac, Horizontal Flame, Cable Flame.
InsulationLabeled or complying with manufacturer's AWM Procedure having a minimum rating of 105 deg C, 1000 Volts.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
JacketExtruded EVA
Diameter of round assembly under jacket in inchesMinimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701 - 1.0004536
1.001 - 1.5006048
1.501 - 2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring or Internal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024