APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2232 Issued:1959-05-01
Revised:2011-09-28
Style 2232 Parallel cable with extruded insulation and jacket.

Rating90 deg C, 600 Vac, FT2 flame. Optional - Oil Resistant 60 deg C or 80 deg C.
ConductorNo. 14, 12 or 10 AWG consisting of No. 30 AWG or smaller tinned or bare copper.
InsulationIntegral with Jacket. Extruded PVC, 70 mils min average, 63 mils minimum at any point.
AssemblyFour conductors, same as type SPT-3. except for a nominal 80 mil wall, the following minimum (pin gauge) dimensions: Wall thickness: 0.070 in., Web thickness: 0.141 in., Wall after rip: 0.058 in..
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of room cooler units where exposed to temperatures not exceeding 90 deg C; or Internal wiring of room cooler units where exposed to temperatures not exceeding 90 deg C and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C; whichever is applicable). Polarity identification may be omitted.