APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22324 Issued:2020-10-09
Revised:New
Style 22324 Multiple conductor with extruded insulation.

Rating105 deg C, 300 Vac, Horizontal flame.
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationExtruded PVC, 6 mils minimum average thickness, 5 mils minimum thickness at any point, thickness measured after split if separable.
AssemblyTwo or more insulated conductors laid parallel, Separable or non-separable construction.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.