Rating | 90 deg C, -40 deg C, 300 Vac, Cable flame, Sunlight Resistance. |
|
Insulated Conductor | Labeled or complying with Manufacturer's AWM Procedure having a minimum rating of 90 deg C, 300 Volts. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701 - 1.000 inch | 45 mils | 36 mils |
| 1.001 - 1.500 inch | 60 mils | 48 mils |
| 1.501 - 2.500 inch | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|