APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22330 Issued:2020-11-17
Revised:2020-12-04
Style 22330 Multi-conductor Flat Ribbon Cable with Extruded Insulation and Extruded Non-Integral Jacket

Rating75 deg C, 60 Vac, Cable Flame, VW-1 flame, HF, LSHF.
ConductorNos. 30 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE, 5 mils minimum average thickness, 4 mils minimum thickness at any point, max average thickness 12 mils. See Facing Page for compound.
AssemblyFour insulated conductor pairs laid flat and parallel with inner Al/polyester shield, drain wire(s), Outer Al/polyester shield and overall FRPE jacket. The minimum distance between the conductor pairs shall be 38 mils and the minimum distance between conductors shall be 14 mils.
Inner ShieldAl/polyester tape shield provided over the complete conductor core - see Facing Page for tape shield designation.
Outer ShieldAl/polyester tape shield provided under the overall jacket - see Facing Page for tape shield designation.
JacketExtruded FRPE, 20 mils minimum average thickness, 16 mils minimum thickness at any point, max average thickness 25 mils. See Facing Page for compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.