Rating | 120 deg C, 600 Vac, Horizontal Flame. |
|
Conductor | 36 AWG - 9 AWG, solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Proedure. |
|
Assembly | Two or more insualted conductors, filler opoitnal. |
|
Shield | Optional - Metal coated Braid |
|
Covering | Optional |
|
Jacket | TPE. |
| Major Diameter of assembly under Jacket* | Minimum average thickness | minimum thickness at any point |
| 0-0.400 inch | 25 mils | 20 mils |
| 0.401-0.700 inch | 30 mils | 24mils |
| 0.701 - 1.000 inch | 45 mils | 36 mils |
| 1.001 - 1.500 inch | 60 mils | 48 mils |
| 1.501 - 2.500 inch | 80 mils | 64 mils |
| 2.500 inch or larger | 110 mils | 88 mils |
| * - Major Diameter if Cable is Flat or Oval. * - See Facing Page for Compound. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|