APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22333 Issued:2020-12-09
Revised:2021-03-29
Style 22333 Multiconductor Cable with Extruded Non-Integral Jacket

Rating120 deg C, 1000 Vac, Horizontal Flame.
Conductor36 AWG - 9 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or More insulated conductors, filler optoinal.
ShieldOptional - Metal coated Braid
CoveringOptional.
JacketTPE.
Major Diameter of assembly under Jacket*Minimum average thicknessminimum thickness at any point
0-0.400 inch25 mils20 mils
0.401-0.700 inch30 mils24mils
0.701 - 1.000 inch45 mils36 mils
1.001 - 1.500 inch60 mils48 mils
1.501 - 2.500 inch80 mils64 mils
2.500 inch or larger110 mils88 mils
* - Major Diameter if Cable is Flat or Oval. * - See Facing Page for Compound.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024