Rating | 90 deg C, 300 Vac, Horizontal Flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded TPE |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inches or less | 30 mils | 24 mils |
| 0.701-1.000 in | 45 mils | 36 mils |
| 1.001-1.500 in | 60 mils | 48 mils |
| 1.501-2.500 in | 80 mils | 64 mils |
| 2.501-4.000 in | 110 mils | 88 mils |
| 4.001 in or larger | 140 mils | 112 mils |
| *Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|