Rating | 90 deg C, 1000 Vac. |
|
Conductor | 26 AWG min., solid or stranded. |
|
Insulation | Labeled or complying with the manufacturer's AWM Procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Covering | Optional. Extruded TPE or other thermoplastic, 4 mils minimum thickness at any point, may be extruded over the conductor assembly or groups of conductors (with or without shields). |
|
Shield | Optional. |
|
Jacket | Extruded TPE |
| Diameter of core assembly under jacket@ | Minimum average thickness | Minium thickness at any point |
| 0.700 or less inch | 45 mils | 36 mils |
| 0.701-1.000 inch | 60 mils | 48 mils |
| 1.001-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
| 2.501 and larger | 140 mils | 112 mils |
| @- Major diameter if cable is flat or oval |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Special. Internal Wiring or External Wiring without a flame rating. |
|