APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22352 Issued:2021-03-17
Revised:New
Style 22352 Multi-conductor cable with non-integral jacket

Rating90 deg C, 1000 Vac.
InsulationLabeled or complying with manufacturer's AWM Procedure.
Assembly Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional.
ShieldOptional.
JacketExtruded TPE
Diameter of core assembly under jacketMinimum average thicknessMinium thickness at any point
0.700 or less inch30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.000 inch110 mils88 mils
4.001 inch or larger140 mils112 mils
* Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial. Internal Wiring without a flame rating.

UL and the UL Logo are trademarks of UL LLC © 2024