APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22370 Issued:2021-03-30
Revised:2021-03-29
Style 22370 Multiple-conductor cable using non-integral jacket.

Rating105 deg C,30 Vac Horizontal flame.
Conductor50 AWG min. Solid or stranded.
InsulationLabeled.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Two or three conductors and or conductor groups may be laid parallel to form flat cable. Manufacturer shall maintain a complete description of each assembly. Insulated conductor is built with optional shield over insulation, optional 1st covering, optional 2nd covering, optional shield over covering and optional 3rd covering.
ShieldOptional.
CoveringOptional.
Metallic BraidOptional.
JacketExtruded PVC, 9 mils minimum average thickness, 7 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024