APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22378 Issued:2021-06-29
Revised:New
Style 22378 Multiple Conductor cable using Non-Integral Extruded Jacket

Rating80 deg C, 300 Vac, Horizontal Flame, FT2 Flame
Conductor50 AWG - 18 AWG, Solid or Stranded Round.
InsulationLabeled or complying with manufacturer's AWM Procedure. Designations of all styles of individual conductor used in making up the cable assembly shall be available.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldAL/PET Foil
BraidMetal Coated Copper
JacketExtruded PVC - 31.5 mils minimum average thickness, 25 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024