APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22381 Issued:2021-08-09
Revised:2021-08-10
Style 22381 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 1000 Vac, Horizontal flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more singles or groups of twisted singles twisted together with overall jacket. Lay not specified. Barrier layer, shield, braid and/or fillers optional.
ShieldOptional.
JacketExtruded TPU -
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.500 inch110 mils88 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial-For use with information technology equipment where the acceptability of the combination is to be determined by Underwriters Laboratories LLC