APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22386 Issued:2021-08-20
Revised:2021-08-19
Style 22386 Multiple-conductor cable employing a non-extruded covering as the outermost layer

Rating80 deg C, 30 Vac, Horizontal flame.
Insulated ConductorLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more insulated singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringInner Covering, Polypropylene film with or without polyester adhesive, one or two sheets, each sheet is 0.5 mil minimum thickness at any point.
ShieldOptional.
CoveringOuter Covering, Polyester film with polyester adhesive, may be applied 1 ~ 3 sheets, 0.5 mils minimum thickness at any point of total tape layers.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.