APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22387 Issued:2021-08-19
Revised:2021-08-31
Style 22387 Multiple Conductor Cable with Non-Extruded Covering

Rating80 deg C, 30 Vac, Horizontal Flame, VW-1 flame.
InsulationLabeled or Complying with the Manufacturer's AWM procedure. Rated for Min. 80C, 30Vac
AssemblyCable Consists of one or more labeled insulated singles and one or more labeled multiconductor components which may consist of multiconductor parallel pairs. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
Inner CoveringOptional - Plastic Tape with max 3 mils thickness
Outer CoveringOptional - Plastic Tape with max 3 mils thickness. Provided over entire core assembly.
Middle ShieldMetal Tape. Provided over outer covering and under Braided Shield.
Outer ShieldTinned Copper Braid. Provided over Metal Tape Shield and under outer non-extruded covering.
CoveringNon-Extruded PET Braid. Each strand of PET covering is minimum 8.6 mils in diameter.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024