| Rating | 80 deg C, 30 Vac, Horizontal Flame, VW-1 flame. |
|
| Insulation | Labeled or Complying with the Manufacturer's AWM procedure. Rated for Min. 80C, 30Vac |
|
| Assembly | Cable Consists of one or more labeled insulated singles and one or more labeled multiconductor components which may consist of multiconductor parallel pairs. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. |
|
| Inner Shield | Metal Tape. Provided over each labeled insulated single or labeled multiconductor components. |
|
| Inner Covering | Optional - Plastic Tape with max 3 mils thickness |
|
| Outer Covering | Optional - Plastic Tape with max 3 mils thickness. Provided over entire core assembly. |
|
| Middle Shield | Metal Tape. Provided over outer covering and under Braided Shield. |
|
| Outer Shield | Tinned Copper Braid. Provided over Metal Tape Shield and under outer non-extruded covering. |
|
| Covering | Non-Extruded PET Braid. Each strand of PET covering is minimum 8.6 mils in diameter. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal Wiring. |
|