Rating | 105 deg C, 300 Vac, Cable flame; 720hr Sunlight Res |
|
Conductor | 40 AWG - 4/0 AWG, solid or stranded. |
|
Insulation | Extruded PVC, 10 mils minimum average thickness, 8 mils minimum thickness at any point. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use mixed sizes of insulated singles. |
|
Shield | Optional - metal shield may be provided over one or more of the insulated conductors or applied over the complete conductor core. |
|
Jacket | PVC - Recognized Component QMTT2 720 Hour Sunlight Resistant PVC Jacket Compound |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 dia | 45 | 36 |
| 1.001-1.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|