APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22390 Issued:2021-09-16
Revised:2021-09-17
Style 22390 Parallel cable with extruded insulation and extruded non-integral covering

Rating80 deg C, 300 Vac.
Conductor42 AWG - 20 AWG, solid or stranded.
InsulationExtruded foamed PE with minimum average thickness 5 mils, minimum thickness at any point 4 mils. A solid PE skin shall be provided under and over the foamed PE insulation. The thicknesses of the skin layers are not specified.
AssemblyThe cable consists of two insulated conductors laid parallel with an overall covering, optional shield layer, optional drain wire, and an overall optional outer covering layer.
Inner CoveringExtruded Solid PE, with minimum average thickness of 4 mils and minimum thickness at any point of 3 mils, shall be provided over the pair of insulated conductors.
ShieldOptional Al PET or Cu PET Tape Shield with 1 mil minimum thickness at any point.
Outer CoveringOptional Outer Layer with Non-extruded PP Tape or PET Tape with 1.4 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.

UL and the UL Logo are trademarks of UL LLC © 2024