APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22395 Issued:2021-11-01
Revised:New
Style 22395 Multiconductor cable with non-extruded covering

Rating105 deg C,30 Vac Horizontal flame.
ConductorSolid or stranded
InsulationLabeled or complying with Manufacturer's AWM Procedure, The minimum voltage and temperature ratings of the singles shall be the rating of the overall cable.
AssemblyTwo or more insulated singles, twisted pair triads or quads laid parallel in one plane, intermittently or continuously bonded together to form a flat ribbon type cable or twisted to form a round cable. Parallel pairs may be shielded. Manufacturer shall maintain a record of all singles used in each cable. May include mixed AWG sizes.
Inner coveringOptional, material and thickness not specified.
ShieldOptional
Outer coveringNon-extruded polyester film with EVA adhesive, 0.5 mils minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024