Rating | 80 deg C, 30 Vac. |
|
Conductor | 42 AWG - 20 AWG, solid or stranded. |
|
Insulation | Extruded Solid PE or FRPE - 3.5 mils minimum average thickness, 3 mils minimum thickness at any point. |
|
Assembly | The cable consists of two insulated conductors laid parallel with an overall covering, optional shield layer, optional drain wire, and an overall optional outer covering layer. |
|
Covering | Extruded Solid PE or FRPE - 3.5 mils minimum average thickness, 3 mils minimum thickness at any point. |
|
Shield | Optional Al PET or Cu PET Tape Shield with 1 mil minimum thickness at any point. |
|
Covering | Optional Outer Layer with PP Tape or PET Tape with 1.4 mils minimum thickness at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|