APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22397 Issued:2021-11-17
Revised:2023-07-09
Style 22397 Parallel cable with extruded insulation and extruded non-integral covering.

Rating80 deg C, 30 Vac.
Conductor42 AWG - 20 AWG, solid or stranded.
InsulationExtruded Solid PE or FRPE - 3.5 mils minimum average thickness, 3 mils minimum thickness at any point.
AssemblyThe cable consists of two insulated conductors laid parallel with an overall covering, optional shield layer, optional drain wire, and an overall optional outer covering layer.
CoveringExtruded Solid PE or FRPE - 3.5 mils minimum average thickness, 3 mils minimum thickness at any point.
ShieldOptional Al PET or Cu PET Tape Shield with 1 mil minimum thickness at any point.
CoveringOptional Outer Layer with PP Tape or PET Tape with 1.4 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseFor Further Processing into Cables.

UL and the UL Logo are trademarks of UL LLC © 2024