Rating | 105 deg C,300 Vac Cable flame, VW-1 flame. |
|
Conductor | 50 AWG min. Solid or Stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure having a minimum rating of 105 deg C, 300 Vac. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Two or three conductors and or conductor groups may be laid parallel to form flat cable. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional |
|
Covering | Optional |
|
Jacket | Extruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
Braid | Optional |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|