APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22398 Issued:2021-12-10
Revised:New
Style 22398 Multiple-conductor cable using non-integral jacket.

Rating105 deg C,300 Vac Cable flame, VW-1 flame.
Conductor50 AWG min. Solid or Stranded.
InsulationLabeled or complying with manufacturer's AWM procedure having a minimum rating of 105 deg C, 300 Vac.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Two or three conductors and or conductor groups may be laid parallel to form flat cable. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional
CoveringOptional
JacketExtruded PVC, 15 mils minimum average thickness, 13 mils minimum thickness at any point.
BraidOptional
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024