APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22406 Issued:2021-12-13
Revised:2021-12-15
Style 22406 Multiple-conductor cable using non-integral jacket

Rating80 deg C, -40 deg C, 600 Vac, Horizontal Flame, 80C Oil
Conductor50 AWG - 4 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's Procedure.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional inner layer
JacketExtruded TPU - See Facing page for Compound
Diameter of Cable under jacket in milsmils min averagemils minimum at any point
0.700 or less3226
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024