APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2241 Issued:1959-05-01
Revised:2012-04-18
Style 2241 Parallel cable with extruded integral insulation and jacket.

Rating60 deg C, 300 Vac, Horizontal flame.
Conductor18 AWG - 16 AWG, stranded.
Integral insulation and jacketExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo conductors, and one dummy filler conductor twisted together.
CoveringOver the insulation shall be applied a wrap consisting of 10 ends of No. 8 two-ply cotton. An outer wrap of 10 ends of 450 denier rayon shall be applied over the inner wrap. The dummy filler conductor shall consist of 26 ends of No. 8 two-ply cotton covered by a wrap of 10 end of 450 denier rayon.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in Portable Lamps.

UL and the UL Logo are trademarks of UL LLC © 2024