APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22411 Issued:2021-12-22
Revised:New
Style 22411 Multiple-conductor cabel using non-integral jacket

Rating80 deg C,60 Vac Cable flame.
Conductor44 AWG - 10 AWG, solid or stranded.
InsulationLabeled, complies with manufacturer's Procedure having minimum ratings of 80 deg C and 60 Vac.
AssemblyTwo or more conductors, twisted pairs, or groups of twisted conductors. The conductors may be laid parallel or twisted together to form a flat, oval, or round cable construction. Barrier layer, tapes and/or fillers optional. May use same or mixed AWG sizes. Manufacturer shall maintain a complete desription of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
2.500 inch or less15 mils12 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring in Class 2 Circuits only.