APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22418 Issued:2022-01-18
Revised:2022-06-21
Style 22418 Multiple Conductor Cable using Non-Integral Non-Extruded Jacket.

Rating90 deg C, 600 Vac.
ConductorStranded Copper, 0.1 mm2 - 4.0 mm2
InsulationExtruded FEP - 14 mils minimum average thickness, 13 mils minimum thickness at any point.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together to form a round cable. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Barrier layer and or fillers are optional.
ShieldBraided Copper, minimum 70% coverage.
JacketNon-Extruded Unsintered PTFE Tape - 6 mils minimum average thickness, 5 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial. External Wiring without a flame rating for use in Cleanroom Machinery where the final use and acceptability is determined by UL LLC.

UL and the UL Logo are trademarks of UL LLC © 2024