| Rating | 90 deg C, 600 Vac. |
|
| Conductor | Stranded Copper, 0.1 mm2 - 4.0 mm2 |
|
| Insulation | Extruded FEP - 14 mils minimum average thickness, 13 mils minimum thickness at any point. |
|
| Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together to form a round cable. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Barrier layer and or fillers are optional. |
|
| Shield | Braided Copper, minimum 70% coverage. |
|
| Jacket | Non-Extruded Unsintered PTFE Tape - 6 mils minimum average thickness, 5 mils minimum thickness at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Special. External Wiring without a flame rating for use in Cleanroom Machinery where the final use and acceptability is determined by UL LLC. |
|