APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2242 Issued:1959-05-01
Revised:2012-03-09
Style 2242 Parallel cable with extruded intergral insulation and jacket

Rating105 deg C, 300 Vac, FT2 flame, Optional - Oil Resistant 60 deg C or 80 deg C.
ConductorNo.20 to 16 AWG consisting of No. 30 AWG or smaller tinned or bare copper strands.
InsulationIntegral with Jacket. Extruded PVC, 45 mils mininum average thickness, 40 mils minimum thickness at any point.
AssemblyTwo or three conductors, same as type SPT-2.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of lighting circuits in electric refrigerators; or internal wiring of lighting circuits in electric refrigerators or where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable), leads for Battery Charges or in appliance Polarity identification may be omitted.