APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22424 Issued:2022-03-18
Revised:New
Style 22424 Multiconductor cable with extruded non-integral jacket

Rating80 deg C,90 Vac VW-1 flame; Cable flame Oil Res 60 (optional); Sunlight Res (optional).
Conductor50 AWG min. solid or stranded.
InsulationLabeled.
AssemblyConsists of two or more conductors, twisted pairs, parallel pairs, or groups of twisted conductors or parallel pairs twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional, Extruded PVC, 6 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC
major dia. in inches
0.400 or less24 mils min average19 mils minimum at any point
0.401-0.700 dia30 avg24 min
0.701-1.500 dia45 avg36 min
1.501-2.500 dia60 avg48 min
*Sunlight Resistant PVC Jackets will be subjected to 720 h Weatherometer Exposure (see Facing Page for jacket compound)
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024