APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22427 Issued:2022-04-28
Revised:New
Style 22427 Multiple-Conductor Cable using Non-Integral Jacket.

Rating80 deg C, 600 V Horizontal flame.
Conductor40 AWG minimum, solid or stranded round, tinned or bare.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or filler are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size.
FillersOptional
ShieldOptional
BraidOptional
CoveringOptional, Extruded FRPE, 23 mils min average, 18 mils minimum at any point.
Flooding CompoundOptional, Gel Flooding compound Unilite may be employed under the jacket.
JacketExtruded FRPE, 23 mils min average, 18 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.