APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22431 Issued:2022-05-17
Revised:2022-05-19
Style 22431 Multiconductor cable with non-extruded covering

Rating80 deg C,30 Vac Horizontal flame.
ConductorSolid or stranded.
Insulated ConductorLabeled or complying with Manufacturer's AWM Procedure, The minimum voltage and temperature ratings of the singles shall be the rating of the overall cable.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
Inner CoveringOptional, material and thickness not specified.
ShieldOptional.
Outer CoveringOne or two layers non-extruded polyester film with polyester adhesive, 0.5 mil minimum average thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024