APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22434 Issued:2022-05-27
Revised:2022-05-26
Style 22434 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 450 Vac.
Conductor40 AWG min. solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of one or more conductors or groups of conductors twisted together. The conductors or groups of conductors may be laid to form anoval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
CoveringInner: Optional - Foamed TPES, 23 mil minimum thickness.
JacketExtruded TPES
Diameter of core assembly under jacketMinimum average thicknessMinium thickness at any point
0.700 or less inch23 mils21 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial. External wiring or internal wiring without a flame rating.

UL and the UL Logo are trademarks of UL LLC © 2024