Rating | 80 deg C, -30 deg C, 300 Vac, Horizontal Flame, 60 deg C Oil Res, Sunlight Res. |
|
Conductor | 32 AWG minimum, solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC, 15 mils minimum average thickness, 12 mils minimum thickness at any point. See Facing Page for Compound. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring. |
|