APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22444 Issued:2022-09-26
Revised:2023-07-11
Style 22444 Parallel cable with extruded insulation and extruded non-integral covering

Rating105 deg C, 30 Vac, Horizontal Flame.
Conductor50 AWG - 20 AWG, Solid or Stranded Round.
InsulationExtruded FEP, with minimum average thickness 2.5 mils and minimum thickness at any point 2 mils.
AssemblyThe cable consists of two insulated conductors laid parallel with an optional inner covering, optional shield layer, optional drain wire, and an overall outer covering layer.
CoveringOptional Inner Layer with Extruded FEP, with minimum average thickness of 2 mils and minimum thickness at any point of 1.5 mils.
ShieldOptional Al PET or Cu PET Tape Shield with 1 mil minimum thickness at any point.
CoveringOuter Layer with PTFE Tape or PET Tape with 0.7 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024