APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22445 Issued:2022-09-26
Revised:2025-02-24
Style 22445 Parallel cable with extruded insulation and extruded non-integral covering

Rating125 deg C, 30 Vac, Horizontal Flame.
Conductor50 AWG - 20 AWG, Solid or Stranded Round.
InsulationExtruded FEP, with minimum average thickness 2.5 mils and minimum thickness at any point 2 mils.
AssemblyThe cable consists of two insulated conductors laid parallel with an optional inner covering, optional shield layer, optional drain wire, and an overall outer covering layer.
CoveringOptional - Inner Layer with Extruded FEP, with minimum average thickness of 2 mils and minimum thickness at any point of 1.5 mils or PTFE Tape, PP Tape, or PET Tape with 0.7 mil minimum thickness at any point.
ShieldOptional - Al PET, Al PP or Cu PET Tape Shield with 1 mil minimum thickness at any point.
CoveringOuter Layer with PTFE Tape or PET Tape with 0.7 mil minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.