APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22449 Issued:2022-10-24
Revised:2022-10-23
Style 22449 Flat ribbon cable

Rating105 deg C,600 Vac Horizontal flame; Oil Res 60,80 (optional).
Conductor2-150, Nos. 32-16 AWG. Tinned or bare, solid or stranded copper, conductors laid parallel and in one plane. Same or mixed AWG.
InsulationExtruded PVC, 9 mils minimum average thickness, 8 mils minimum thickness at any point.
AssemblyTwo to one hundred and fifty conductors laid parallel and in one plane. May use same or mixed AWG size. Minimum average and minimum at any point of insulation thickness after ripping shall be 9 mils and 8 mils, respectively. This forms a flat cable with a single row of conductors having a 1/2 in. maximum width web between insulated conductors.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.