APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22455 Issued:2023-02-06
Revised:New
Style 22455 Multiple Conductor Cable with Non-Integral Extruded Jacket

Rating80 deg C, 600 Vac, Cable Flame
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC/TPU
Diameter of cable under jacket in inchesminimum average thickness in milsminimum thickness at any point in mils
0.700 or less3024
0.701-1.0006048
1.001-1.5018064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024