|
Rating | 90 deg C,-40 deg C,90 Vac Cable flame; Sunlight Res (required). |
|
Conductor | 50 AWG - 20 AWG, solid or stranded. |
|
Insulation | Extruded FRPE, 5 mils minimum average thickness, 4 mils minimum thickness at any point. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. See Facing Page for compound. |
| Diameter of Core Assembly under jacket in inches | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.000-0.400 | 24 | 19 |
| 0.401-0.700 | 30 | 24 |
| 0.701-1.500 | 45 | 36 |
| 1.501-2.500 | 60 | 48 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External Wiring. |
|