APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 22459 Issued:2023-03-03
Revised:2023-03-23
Style 22459 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 90 Vac Cable flame.
Conductor50 AWG - 10 AWG, Solid or stranded.
InsulationLabeled or complying with the manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated wires or groups or individually insulated wires forming a round, oval or flat cable. The length of lay of the twisted wires or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketTPU
Diameter of core assembly under jacket(inches)*Minimum average thickness(mils)Minimum thickness at any point(mils)
0 - 2.5001512
*Major diameter if cable is flat or oval.
Outermost BraidOptional, Polyester.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring in Class 2 circuits.

UL and the UL Logo are trademarks of UL LLC © 2024